KLIPR 8 mm LED Tape Connector 24 V
Product # 30141094
For uncoated IP22 tape light
The KLIPR system facilitates the insertion of wires or tape lighting.
The system allows customers to make connections when and where needed, with different direct connections to tape or with a wire up to 2 m (6.6' or 79") long.
The system allows customers to make connections when and where needed, with different direct connections to tape or with a wire up to 2 m (6.6' or 79") long.
ADVANTAGES AND BENEFITS
Customize your wire lengths as needed
REQUIRED PRODUCTS
Requires ONE of the following products
LED 24 V Tape Light
- Light Color: Warm White
- Kelvin Color Temperature (K): 3000 K
- CRI (Color Rendering Index): 92.3
- Luminous Efficiency: 84.5 lm/W
OR
LED 24 V Tape Light
- Light Color: Neutral White
- Kelvin Color Temperature (K): 4000 K
- CRI (Color Rendering Index): 94
- Luminous Efficiency: 84.4 lm/W
Requires ONE of the following products
LED Tape 4.8 W/m 24 V
- Light Color: Warm White
- Kelvin Color Temperature (K): 3000 K
- Luminous Efficiency: 82 lm/W
OR
LED Tape 4.8 W/m 24 V
- Light Color: Neutral White
- Kelvin Color Temperature (K): 4100 K
- Luminous Efficiency: 80 lm/W
Requires ONE of the following products
LED Tape 9.6 W/m 24 V
- Light Color: Warm White
- Kelvin Color Temperature (K): 3000 K
OR
LED Tape 9.6 W/m 24 V
- Light Color: Neutral White
- Kelvin Color Temperature (K): 4100 K
TECHNICAL SPECIFICATIONS
Product #
30141094
Lighting Type
LED
Compatibility
Micro 24
Tension (V)
24 V
Function
Connecting Cable
Length
78 3/4 in*
Group
LED Group A, Klipr
Disclaimer
Measures shown with an asterisk (*) have been converted as per your preference. These are not the official measures. To view the measures specified by the manufacturer, click here.
IMPORTANT INFORMATION
For uncoated 8 mm IP22 tape light
Class 2
100 W max
24 V, 4 A max
A 1" heat shrink sleeve (not included), class 300 V / 125 °C, must be installed on each connector to avoid bad connections.
Compatible cable 20-22AWG type TR64, 300 V.
Installation must be done by qualified personnel.
Class 2
100 W max
24 V, 4 A max
A 1" heat shrink sleeve (not included), class 300 V / 125 °C, must be installed on each connector to avoid bad connections.
Compatible cable 20-22AWG type TR64, 300 V.
Installation must be done by qualified personnel.