CS Door Collection System

To add to cart, choose from the options below.

Slide and stack multiple doors

The Cavity Sliders CS Door Collection System is designed for sliding telescopic doors and for stacking multiple parallel wood doors weighing up to 200 lb (90 kg) and 500 lb (227 kg) each.

Features:
- Available in two- and three-door hardware set packs
- One-piece track options for double and triple spaced doors with a 1 3/8 in (35 mm) and 1 3/4 in (45 mm) thickness
- Bottom guide brackets link doors so that floor guide channels are not necessary
- Vertical "pick-up" aluminum profiles are standard 92 in (2336 mm) tall and ensure a secure and stable link between doors for a smooth transition from one door the next. The profiles can be cut to size.
- Recessed floor guide channels and guide are available for extra wide doors

Ideal for residential and commercial applications for small and large room dividers, multiple door closets and storage units, meeting rooms, multifunctional rooms, and open space planning.
Load Capacity: 90.7 kg* 227 kg* Door Thickness: 34.9 mm* 44.5 mm* Overall Length: 30.5 cm* 1.83 m* 2.44 m* 3.66 m* 4.88 m* 7.32 m* Number of Doors: 2 3 4 6 Select Options
Product # Load Capacity Door Thickness Overall Length Number of Doors
WEBKIT1248297 90.7 kg* 34.9 mm* 1.83 m* 2
WEBKIT1248298 90.7 kg* 34.9 mm* 2.44 m* 2
WEBKIT1248299 90.7 kg* 34.9 mm* 2.44 m* 3
WEBKIT1243881 90.7 kg* 34.9 mm* 3.66 m* 2
WEBKIT1243882 90.7 kg* 34.9 mm* 3.66 m* 3
WEBKIT1240094 90.7 kg* 44.5 mm* 1.83 m* 2
WEBKIT1240095 90.7 kg* 44.5 mm* 2.44 m* 2
WEBKIT1240101 90.7 kg* 44.5 mm* 2.44 m* 3
WEBKIT1240102 90.7 kg* 44.5 mm* 3.66 m* 3
WEBKIT1240096 90.7 kg* 44.5 mm* 4.88 m* 4
WEBKIT1240103 90.7 kg* 44.5 mm* 7.32 m* 6
WEBKIT1248301 227 kg* 34.9 mm* 30.5 cm* 2
WEBKIT1248300 227 kg* 34.9 mm* 2.44 m* 2
WEBKIT1243885 227 kg* 34.9 mm* 3.66 m* 3
WEBKIT1248302 227 kg* 34.9 mm* 4.88 m* 6
WEBKIT1240098 227 kg* 44.5 mm* 3.66 m* 2
WEBKIT1240105 227 kg* 44.5 mm* 3.66 m* 3
WEBKIT1240099 227 kg* 44.5 mm* 7.32 m* 4
WEBKIT1240106 227 kg* 44.5 mm* 7.32 m* 6

ADVANTAGES AND BENEFITS

- Bottom guide brackets link doors so that floor guide channels are not necessary
- Vertical "pick-up" aluminum profiles are standard 92 in (2336 mm) tall and ensure a secure and stable link between doors for a smooth transition from one door the next. The profiles can be cut to size.

TECHNICAL SPECIFICATIONS

Door Material
Wood
Door Movement
Movable Wall
Detailed Door Movement
Biparting, Telescoping
Track Mounting
Ceiling Mount
Roller Type
Ball Bearing
Roller Position
Upper
Application
Screen Panel
Brand
Cavity Sliders
Track type
Box Track
Running Track Fixing
Surface and Recessed
Manufacturing Material
Aluminum
Adjustable
Yes
Soft-Closing
No
Displayed in These Showrooms
Ottawa
Door Installation
Top Hung
Door Height
3.2 m*
Door Width
55.9 to 132 cm*
Disclaimer

Measures shown with an asterisk (*) have been converted as per your preference. These are not the official measures. To view the measures specified by the manufacturer, click here.

DISCLAIMER

Please make sure to read the entirety of the installation manual before proceeding with the installation. #8 screws and appropriate anchors required for installation (not included). A groove is required for the bottom of the door for the floor guide, see instructions. Wear safety gear such as gloves, safety glasses, safety shoes, and ear protection. See instructions for rough opening and other dimensions. Do not exceed stated limitations and parameters. This will cause early wear and performance failure, and will void the warranty.

- Pictures provided for visual reference only: actual product may vary.
- All required hardware should be ordered and obtained prior to initiating fabrication or installation work. Please verify that the parts and quantities listed in your order are correct before proceeding to checkout.
- Always use instructions provided by the manufacturer, as included with the product. Manufacturer reserves the right to amend, modify, or otherwise supplement any previously issued product and/or technical information, as deemed required from time to time, without prior notice.
- The documentation, drawings, and instructions on this page apply to the system described on this page only. Richelieu expressly declines all responsibility for any design or construction that combines this system with systems from this same manufacturer or systems from other manufacturers.
- Installation of the product shall be executed by qualified individuals only, always ensuring that each product is securely installed using proper fixation methods, as appropriate for each applicable substratum. We trust that anyone installing these products has the required skills, knowledge, and experience. Richelieu expressly disclaims any liabilities for results obtained through improper use or installation.
- Always remove debris/dust/residues (sawdust and/or aluminum) from all tracks and guide channels using a dry cloth during installation and before operating the system.
- Never spray lubricant on this product.